Приказ основних података о документу

dc.creatorŠinik, Vladimir
dc.creatorDespotović, Željko
dc.creatorKetin, Sonja
dc.creatorMarčeta, Una
dc.date.accessioned2024-04-03T14:40:26Z
dc.date.available2024-04-03T14:40:26Z
dc.date.issued2020
dc.identifier.issn1584-2665 2601-2332
dc.identifier.urihttps://intam.institut-tamis.rs/handle/123456789/309
dc.description.abstractThis paper analyzes the sources of time-varying electrical and magnetic fields of industrial frequency. Therefore, very low frequency electromagnetic fields in our environment are analyzed. This refers to the power system, overhead power lines, transformer stations, electrical installations and household electrical appliances. The results of magnetic induction measurements of electrical household appliances (hair dryer, vacuum cleaner, water heater, electric cooker, aspirator, mixer, coffee grinder, mobile charger) are given, depending on the distance from the device.sr
dc.language.isoensr
dc.publisherTimisoara (Romania) : University Politehnica Timisoara, Faculty of engineering Hunedoarasr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceANNALS of Faculty Engineering Hunedoara – International Journal of Engineeringsr
dc.subjectfields of industrial frequencysr
dc.subjectmeasurementssr
dc.subjectelectrical household appliancessr
dc.titleRadiation of electromagnetic fields of industrial frequencies. Electromagnetic radiation of electrical appliances in householdssr
dc.typearticlesr
dc.rights.licenseBYsr
dc.citation.epage18
dc.citation.spage13
dc.identifier.fulltexthttp://intam.institut-tamis.rs/bitstream/id/379/ANNALS-2020-1-01.pdf